Meters of direct current 3,5
(Ù00, Ù00.02) - Meters of direct and alternating current with galvanic isolation 3,5 (Ù01, Ù01.03, Ù01.04, Ù01.05, Ù01.06, Ù02.01) - Meters of direct and alternating current with galvanic isolation 4,0; 4,5 (Ù01, Ù01.04, Ù01.06) - Meters of direct and alternating current with galvanic isolation, RS-485 with discharge 4,0; 4,5 (Ù02, Ù02.04, Ù02.06) |
Meters of direct and alternating current with galvanic isolation,
RS-485 with discharge 4,0; 4,5
![]() Ù02.04 120õ120õ50 mm |
![]() Ù02.06 96õ96õ56 mm |
|
Accuracy: - for direct current meters: with discharge 4,5 (max 19999) - 0,1 with discharge 4,0 (max 9999) - 0,2 - for alternating meters - 0.5 Consumed power - not more than 1,2 Âò. For direct current meters - autopolarity ÒÓ25-7504.156-2001. Frequency band of measuring signals: - of alternating current 40 - 1000 Hz - of alternating voltage 40 - 10000 Hz |
Commentary |
|||||||||
Ù | -ٱ | -ٱ | -ٱ | -ٱ | -ٱ | -ٱ | -ٱ | -ٱ | Base version |
- | Direct current | ||||||||
A | Alternating current | ||||||||
01 | 24x96x90 mm | ||||||||
01.04 | 120õ120õ50 mm | ||||||||
01.06 | 96õ96õ56 mm | ||||||||
Measurement range |
Discharge | ||||||||
1mA | 4,0 | ||||||||
2mA | 4,5 | ||||||||
10mA | 4,0 | ||||||||
20mA | 4,5 | ||||||||
100mA | 4,0 | ||||||||
200mA | 4,5 | ||||||||
1A | 4,0 | ||||||||
2A | 4,5 | ||||||||
10A | 4,0 |
Direct current - through shunt for 75mV Alternating current -through current - transformer with coefficient 10/1, 20/2, 100/1, 200/2, 1000/1, 2000/2 |
|||||||
20A | 4,5 | ||||||||
100A | 4,0 | ||||||||
200A | 4,5 | ||||||||
1000A | 4,0 | ||||||||
2000A | 4,5 | ||||||||
100mV | 4,0 | ||||||||
200mV | 4,5 | ||||||||
1V | 4,0 | ||||||||
2V | 4,5 | ||||||||
10V | 4,0 | ||||||||
20V | 4,5 | ||||||||
100V/b> | |||||||||
200V | 4,5 | ||||||||
750V | 4,0 | ||||||||
+ 5V | Power supply | ||||||||
RS-485 | RS-485 | ||||||||
- | Without RS-485 | ||||||||
GI | Galvanical isolation | ||||||||
- | Without galvanical isolation | ||||||||
Example order: | R | Red indicator | |||||||
Ù02-200mV-4,5-5V-GI-R | G | Green indicator | |||||||
Y | Yellow indicator | ||||||||
O | Other indicator |
Supplies for digital meters
Item |
Voltage of supply |
Output voltage |
Load current |
Overall dimentions (in package of Ù02.01) |
ÁÏË5-1 (for supply of 1 meter, 1 channel) |
220 V |
5 V |
200 mA |
48x96x90 mm |
ÁÏË5-2 (for supply of 2 meters, 2 channels) |
220 V |
5 V |
2õ200 mA |
48x96x90 mm |
ÁÏÈ5-1-1 (for supply of 4 meters) |
160 - 240 V |
5 V |
1 A |
48x96x90 mm |
ÁÏÈ5-1-3 (for supply of 10 meters) |
160 - 240 V |
5 V |
3 A |
48x96x90 mm |