Wattmeter and Varmeter

Purpose


       Wattmeters and varmeters Ö42303 are intended for measureing of active and reactivecapacity in three-phase three-wire circuits of an alternating current by frequency 50 Hz and 60 Hz at uniform and non-uniform loading of phase.
       Wattmeters and varmeters are executed on the basis of the electronic converter of capacity in a signal of a direct current and the magnitoelectric device.

    The instruction on registration of the order

Operational parameters

Type instruments

Range of measurement

Accuracy class

Overall dimensions, mass

Operating condition

Switch on method

Ö42303

For a wattmeter cosf=1

1,5

120x120x95 mm

0,9 kg

Temperature -40...+50°Ñ
relative humidity of 95%
at temperature
+ 30 °Ñ.
Crashworthiness:
acceleration 70 m/s2
at frequency of impacts 10...50 Hz.
Vibrostability:
acceleration 15 m/s2
at frequency 30 Hz.
Service life is not less then 10 years.

Directly on a voltage 127, 220,
380V;
a current 5À

through the measuring transformer on a voltage 100V;
a current 1; 5A

For a warmeter
sinf=1