ÝÀ0701 Drawing |
ÝÀ0700 Drawing |
ÝÀ0702 Drawing |
Type instruments | Range of measurement | Accuracy class | Overall dimensions, mass | Operating condition | Switch
on method |
ÝÀ0700 | A -1; 2; 3; 5; 10 | 1,5 2,5 | 80x80x50 mm 0,15 kg | Temperature -30...+50oC, relative humidity 95% at +35oC. Vibration strength: acceleration 5...30 m/s2, frequency 10...70 Hz. Shock resistance: acceleration 70 m/s2, Shock frequency 10 to 50 / min. Normal frequency 50 (180 - 550), 60 (180-550), 800, 1000 Hz. | Direct |
ÝÀ0701 | A -20; 30; 50; 75; 100; 150; 200; 300; 400; 600; 800; 1000; 1500; 2000; 3000; 4000; 5000 | 60x60x50 mm 0,12 kg | Throught secondary winding current transformer 5 A | ||
ÝÀ0702 | A -1; 2; 3; 5; 10 | 1,5 | 120x120x50 mm 0,35 kg | Temperature -40...+50oC, relative humidity 95% at +35oC. Vibration strength: acceleration 15 m/s2, frequency 30 Hz. Vibration resistanse: acceleration 5 m/s2, frecuency 20 Hz. Shock resistance: acceleration 70 m/s2, Shock frequency 10 to 50 / min. Normal frequency 50, 60, 200, 500, 1000 Hz. | Direct |
A -20; 50; 600; 1000 | With secondary winding current transformer 1 A | ||||
A* -10; 15; 20; 30; 40; 50; 75; 80; 100; 150; 200; 250; 300; 400; 500; 600; 750; 800; 1000; 1200; 1500; 2000; 3000; 4000; 5000; 6000; 8000; 10000 | With secondary winding current transformer 5 A | ||||
Load ammeter ÝÀ0702 (Load with factor 6) | A -1; 3; 5; 10 | Direct | |||
A* -1 | With secondary winding current transformer 1 A | ||||
A* -5; 10; 15; 20; 30; 40; 50; 75;
80; 100; 150; kA* -0,2; 0,25; 0,3; 0,4; 0,5; 0,6; 0,75; 0,8; 1; 1,5; 2; 3; 4; 5; 6; 8; 10 | With secondary winding current transformer 5 A | ||||
* - It is possible to manufacture the meters with other upper measurment
range; It is also possible to make meters for the switching on the meters throught the secondary winding current transformer 1 À |