M42300, M4250, M42175 | M42301, M4251 | M4263 |
Type instruments | Range of measurment | Accuracy class | Overall dimensions, mass | Operating condition | Switch on method |
Direct | |||||
M42300 | mA - 1; 5; 10; 15; 30; 50; 100; 150; 300; 500; 600; 3/30; 3/50; 5/50 A-1; 2; 3; 5; 10; 15 | 1,5 2,5 | 80x80x50 mm, 0,15 kg | Temperature -50...+60оС, relative humidity 95% at +35оС. Vibration strength: acceleration 5...30 m/s2, frequency 10...70 Hz. Shock resistance: acceleration 100 m/s2, Shock frequency 10 to 50 / min. |
|
M42301 | A - 20; 30; 50; 75; 100; 150; 200; 300; 500; 750; 1000; 1500; 2000; 4000; 6000; 200-0-75 | 60x60x50 mm, 0,12 kg | With the external calibrated shunt 75ШИC and calibrated wires | ||
V - 0,075 | With calibrated wires, impedance R=0,035W | ||||
V - 2; 3; 7,5; 10; 15; 20; 30; 50; 75; 100; 150; 250; 300; 500; 600; 3/30; 3/300; 30/300; 4/100; 7,5/300; 8/300; 10/100; 15/150; 15/300; 20/40 | Direct | ||||
V - 0-150/1500; 15/150/1500; 1000; 1500; 3000 | With separated calibrated series resistor P4201, nominal current 5 mA | ||||
M4250 | mA - 1; 5; 10; 15; 30; 50; 100; 150; 300; 500; 600 mA - 3/30; 3/50; 5/50 A - 1; 2; 3; 5; 10 | 1,5 2,5 | 80x80x49 mm 0,20 kg | Temperature -50...+60оС, relative humidity 95% at +40оС. Shock resistance: acceleration 100...750 m/s2, Shock frequency 80...120 / min. Vibration strength: acceleration 2...20 m/s2, frequency 10...40 Hz. | Direct |
M4251 | A - 20; 30; 50; 75; 100; 150; 200; 300; 500; 750; 1000; 1500; 2000; 4000; 6000 | 60x60x49 mm, 0,15 kg | With the external calibrated shunt 75ШИC and calibrated wires | ||
V - 1; 2; 3; 7,5; 10; 15; 30; 50; 75; 100; 150; 250; 300; 500; 600; 3/30; 3/100; 3/300; 7,5/300; 8/300; 10/100; 15/150; 15/300; 30/300 | Direct | ||||
V - 1000; 1500; 3000 | With separated calibrated series resistor P4201, nominal current 5 mA | ||||
M4263 | mA - 1; 5; 10; 15; 30; 50; 100; 150; 300; 500; 600; A - 1; 2; 3; 5; 7,5; 10 | 1,5 2,5 | 60x60x48 mm, 0,105 kg | Temperature -50...+60оС, relative humidity 95% at +35оC. Vibration strength: acceleration 5...30 m/s2, frequency 10...70 Hz. Shock resistance: acceleration 100 m/s2, Shock frequency 10 to 50 / min. | Direct |
A - 20; 30; 50; 75; 100; 150; 200; 300; 500; 750; 1000; 1500; 2000; 4000; 6000 | With the external calibrated shunt 75ШИC and calibrated wires | ||||
V - 1; 2; 3; 7,5; 10; 15; 30; 50; 75; 100; 150; 250; 300; 400; 500; 600 | Direct | ||||
V - 1000; 1500; 3000 | With separated calibrated series resistor P4201, nominal current 5 mA | ||||
M42175 | A - 1; 2; 3; 5; 10 | 4,0 | 80x80x50 mm, 0,15 kg | Temperature -10...+40oC, relative humidity 90% at +30oC | Direct |
A - 50 | With the external calibrated shunt 75ШИC and calibrated wires |