Properties
|
- Designed on the base of monocristal microcomputer
- Digital indication of measurement based on LCD indicator (16x4 symbols)
- Spared mode of current effective value of the single-phase short circuit (pulse
instantaneous current value is not more than 100A in the measuring circuit)
- 120 measurement results being preserved and printed when power is switched- off
- Remote control by means of the personal computer and information measuring system structure
- Case protection degree in accordance with GOST 14254-IP30
|
Operating condition |
- Ambient air temperature:
from -10°C up to +40°C;
- Relative air humidity: 80% at
25° Ñ;
- Atmospheric pressure: 84…106,7
kPa (630…800 mm Hg).
|
ÝÊ0604 measures
|
- effective value of mains voltage (U)
- network frequency (F)
- current effective value of the single-phase short circuit (SC) to "ground" and
"Z"
- phase-shift between voltage and current of the single-phase short-circuit (j),
and cosj
- disconnecting differential current of the protective disconnection device (ID n)
- disconnection time of the protective disconnection device (T)
- direct-current resistance (R)
|
Measurement
and error ranges |
U= 50…300V |
d
= ±
1% |
ID
n = 30 mA |
d
= ± 4% |
F = 45,00…55,00 Hz |
d
= ±
0,3% |
ID
n = 100 mA |
d
= ± 2% |
ISC
= 50…2000 A |
d
= ±
10% |
ID
n = 300 mA |
d
= ± 2% |
j
= 1…30° |
d
= ± 10% |
ID
n = 500 mA |
d
= ± 2% |
cos j
= 1,0000…0,8660 |
d
= ± 10% |
T = 0,010…10,000 s |
d
= ± 0,3% |
ID
n = 6 mA |
d
= ± 10% |
R = 0,100…1000 Om |
d = ± 1% |
ID
n = 10 mA |
d = ± 10% |
|
|
Overall dimensions - 290x230x120 mm
Mass, not more - 3,8 kg
Power sorce - 220 V, 50 Hz |
Power consumption - 50 VA
Mean-time-between - 10 yeares
Mean serice life - 2500 h |
|